21
gt7_mb (12A1)
MB126
10 Technical data
10.1 General data
• Performance: GT 7.08: 0.3 W (speed >5,000 rpm)
GT 7.16: 0.6 W (speed >5,000 rpm)
• Calibration tolerance: ±5%
• Linearity tolerance: ≤0.15%
• Reversing tolerance: ≤0.1%
• Superimposed ripple: ≤0.6% peak-peak
(for τ
RC
= 0.3 ms) ≤0.25% rms
• Temperature coefcient: ±0.05%/K (idle)
• Armature-circuit time-constant (τ
A
): ≤4 µs
• Open-circuit voltage: 10...60 mV per rpm
• Torque: 1.5 Ncm
• Rotor moment of inertia: GT 7.08: 0.4 kgcm
2
GT 7.16: 0.6 kgcm
2
• Permissible armature displacement: ±0.5 mm axial
±0.1 mm radial
• Vibration resistance: 100 m/s
2
≈ 10 g EN 60068-2-6: 1996-05
(10-2000 Hz)
• Shock resistance: 1,000 m/s
2
≈ 100 g EN 60068-2-27: 1995-03
(6 ms)
• Operating temperature: -30°C...+130°C
• Isolation class: B
• Protection class IEC 60529: IP 55
• Climatic tests: IEC 60068-2-3, Ca (dump heat, constant)
• Weight approx.: GT 7.08: 110 g
GT 7.16: 160 g
• EMC according to:
EN 61000-6-2: 2006-03 (interference immunity)
EN 61000-6-4: 2007-09 (emitted interference)
10 Technical data