gt7_mb (12A1)
MB126
10 Technical data
10.1 General data
Performance: GT 7.08: 0.3 W (speed >5,000 rpm)
GT 7.16: 0.6 W (speed >5,000 rpm)
Calibration tolerance: ±5%
Linearity tolerance: 0.15%
Reversing tolerance: 0.1%
Superimposed ripple: 0.6% peak-peak
(for τ
RC
= 0.3 ms) 0.25% rms
Temperature coefcient: ±0.05%/K (idle)
Armature-circuit time-constant (τ
A
): 4 µs
Open-circuit voltage: 10...60 mV per rpm
Torque: 1.5 Ncm
Rotor moment of inertia: GT 7.08: 0.4 kgcm
2
GT 7.16: 0.6 kgcm
2
Permissible armature displacement: ±0.5 mm axial
±0.1 mm radial
Vibration resistance: 100 m/s
2
≈ 10 g EN 60068-2-6: 1996-05
(10-2000 Hz)
Shock resistance: 1,000 m/s
2
≈ 100 g EN 60068-2-27: 1995-03
(6 ms)
Operating temperature: -30°C...+130°C
Isolation class: B
Protection class IEC 60529: IP 55
Climatic tests: IEC 60068-2-3, Ca (dump heat, constant)
Weight approx.: GT 7.08: 110 g
GT 7.16: 160 g
EMC according to:
EN 61000-6-2: 2006-03 (interference immunity)
EN 61000-6-4: 2007-09 (emitted interference)
10 Technical data