10 www.baumer.com
ISI30, ISI31, ISI32, ISI33
Screw terminal 3:
R
eset input, active for negative edge Contact input / Open
Collector NPN (switching at 0 V DC)
Low level: 0 ... 0,7 V DC
High level: 3 ... 30 V DC
M
in. pulse duration: 50 ms
I
nput resistance: approximately 2,2 MOhm
S
crew terminal 5:
O
perating mode switch (Mode) Contact input / Open Collector
NPN (switching at 0 V DC)
Low level: 0 ... 0,7 V DC
H
igh level: 3 ... 5 V DC
Input resistance: approximately 2,2 MOhm
Function: see Table 2
Screw terminal 4:
E
lectrical locking of the reset key Contact input / Open Collector
NPN (switching at 0 V DC)
Low level: 0 ... 0,7 V DC
High level: 3 ... 5 V DC
I
nput resistance: approximately. 2,2 MOhm
I
nput not active: Reset key locked
I
nput in contact
w
ith GND: Reset key unlocked
Screw terminal 6:
GND connection common for all inputs
Screw terminal 7:
(–) external power supply for the LCD backlight option
Screw terminal 8:
(+) external power supply for the LCD backlight option
(24 V DC
±
20%, 50 mA)
Input specification and pin assignment (AC-version)
Screw terminal No. 1
INP A
AC/DC
No. 2
No. 3
INP B AC/DC
No. 4 No 5 No. 6
No. 7
No. 8
ISI30.013AX01
ISI31.013AX01
ISI32.013AX01
counting
Common connec-
tion for INP A and
INP B
Reset Enable
NPN reset key lok-
king input, Contact
with GND. key free.
not connected
NPN reset input
GND =
0 V DC
Backlighting (–)
Backlighting (+)
Screw terminals 1 and 3:
Function: see Table 3
Optocoupler input 10 ... 260 V AC/V DC
galvanic isolation, active for high signal
Min. pulse duration: 16 ms
Max frequency: approximately 30 Hz
Low level: 0 ... 2 V AC/V DC
High level: 10 ... 260 V AC/V DC
Input resistance: approximately 160 kOhm
Screw terminal 2:
Common AC/DC, common connection for the optocoupler inputs
(screw terminals 1 and 3).
Screw terminal 4:
Electrical locking of the reset key Contact input / Open
Collector NPN (switching at 0 V DC)
Low level: 0 ... 0,7 V DC
High level: 3 ... 5 V DC
Input resistance: approximately 2,2 MOhm
Input not active: Reset key locked
Input in contact with GND:
Reset key unlocked
Screw terminal 5:
Function: see table 3, active for negative edge Contact input
/ Open Collector NPN (switching at 0 V DC)
Low level: 0 ... 0,7 V DC
High level: 3 ... 5 V DC
Min. pulse duration:
50 ms
Input resistance: approximately 2,2 MOhm
Input high: - - -
Input low : Reset of the counter
Dynamic resetting behaviour
Screw terminal 6:
Common GND connection for screw terminal 4 (reset key
locking input) and screw terminal 5 (reset input).
Screw terminal 7:
(–) external power supply for the backlight option
Screw terminal 8:
(+) external power supply for the backlight option
(24 V ±20%, 50 mA)
Designation
Model
Common
AC/DC
Reset GND BL
–
BL
+
adding
subtracting
counting
direction
reset
counting
Table 3