8 www.baumer.com
ISI30, ISI31, ISI32, ISI33
Options: x = A: no backlight
x = B: with backlight
DC input modes:
Count: Fast and slow counting inputs
INP A: Fast counting input
INP B: Slow counting input
Cnt.Dir: Counting and counting direction input
INP A: Counting input
INP B: Counting direction input
Up.Dn: Differential counting input
INP A: Adding counting input
INP B: Subtracting counting input
Quad: Phase discriminator input
INP A: counting input
INP B: 90° counting input
Quad2: Phase discriminator input with
pulse doubling
INP A: counting input
INP B: 90° counting input
Each edge of INP A is counted.
AC input modes:
Count: Counting and reset inputs
INP A: AC/DC counting input
INP B: AC/DC reset input
Cnt.Dir: Counting and counting direction input
INP A: AC/DC counting direction input
INP B: AC/DC counting input
Up.Dn: Differential counting input
INP A: AC/DC subtracting counting input
INP B: AC/DC adding counting input.
Table 1
Model Operating mode
Counting inputs
INP A
INP B
ISI30.010AX01
ISI30.012AX01
ISI30.013AX01
ISI31.010AX01
ISI31.011AX01
ISI31.013AX01 AC/DC
ISI32.013AX01
ISI33.010AX01
ISI33.011AX01
Count
00 ... 0,7 V DC
NPN 7 kHz
00 ... 0,7 V DC
NPN 30 Hz
10 ... 260 V AC/DC AC/DC 30 Hz
Cnt.Dir/Up.Dn
Up.Dn
Cnt.Dir
Quad/Quad2
NPN
PNP
AC/DC
NPN
PNP
00 ... 0,7 V DC
04 ... 30 V DC
10 ... 260 V AC/DC
10 ... 260 V AC/DC
00 ... 0,7 V DC
04 ... 30 V DC
7 kHz
12 kHz
30
Hz
30 Hz
3 kHz
6 kHz
00 ... 0,7 V DC
10 ... 260 V AC/DC
00 ... 0,7 V DC
04 ... 30 V DC
10 ... 260 V AC/DC
10 ... 260 V AC/DC
00 ... 0,7 V DC
04 ... 30 V DC
NPN
AC/DC
NPN
PNP
AC/DC
AC/DC
NPN
PNP
7 kHz
12 kHz
30 Hz
30 Hz
3 kHz
6 kHz
04 ... 30 V DC
PNP
12 kHz
Overview
0
1.9 Start-up
Is the device set and programmed correctly (function; for coun-
ters, max. counting frequency)?
1.10 Failure possibilities and causes
Impossible to use the keys:
-
Key lock input activated
Counter does not count:
-
Wrong or reversed wiring of the counting input
-
Setting of an input signal not matching the pulse generator
- Polarity (NPN/PNP) reversed
- No ground connection between the pulse generator and the
c
ounter
- Signal levels do not reach the switching threshold of the counter
If, despite all, your device still does not operate, contact your
l
ocal representative or call us directly for technical support.
W
hen sending your device back, please attach a short descrip-
t
ion of the failure, of the programming and of the connection
d
iagram, in order to allow us to reproduce a possibly existing
defect and to repair your device as quickly as possible.